Conform to the ISO (International Standards), JIS (Japanese Industrial Standard), ASTM (American Society for Testing and
Electrolytic coating thickness gauge
Product Details

Conform to the ISO (International Standards), JIS (Japanese Industrial Standard), ASTM (American Society for Testing and Materials), MIL (Military Standard), DIN (Germany standard) in the world generic thickness analyzer.

To test non-magnetic substrate on the magnetic coating is as follows:
Copper, nickel, nickel two-story, three-tier nickel, chemical nickel, chromium, platinum chrome, black
chrome, gold, silver, tin, zinc, cobalt, iron, cadmium, lead, indium and tin-lead alloy, nickel-cobalt alloy, tin-
zinc alloy, copper-zinc alloy and iron-nickel alloy coating.

SPEC
Measurement range 0.006~300¦Ìm
Resolution 0.001¦Ìm
Measurement units ¦Ìm,nm,mil,MI£®
In the area of peace prevail ¦Õ1.7,¦Õ2.4,¦Õ3.4mm
Electrolysis speed 250,125,50,25,12.5,5,2.5,1.25nm/sec
Accuracy ±1%
Host size 300x250x150mm  Weight:3Kg
Power 100/220V±1OV,50/60HZ